Fig. 6From: Validation of an equine serum amyloid A assay with an unusually broad working rangeSerum concentrations of serum amyloid A (SAA) determined in horses undergoing castration and experimental systemic inflammation. Individual (grey lines) and average (black lines, error bars show standard deviations) serum amyloid A (SAA) concentrations in 12 horses before and 1, 2, 3 and 8 days after castration (a) and in 7 horses before and 4, 8, 12, 16, 24, 36, 48, 72, 96, 120 and 144 h after IV injection of lipopolysaccharide (LPS) (b). Serum concentrations of SAA were determined by means of an immunotubidometric assay developed for determination of SAA concentrations in horses (VET-SAA)Back to article page