Skip to main content

Table 4 Pairwise comparison of FluDETECT positive sample proportions for different sample pooling schemes for RT-PCR positive samples (i.e., those with CT ≤ 35) using one-sided Fisher’s exact test

From: Quantifying the effect of swab pool size on the detection of influenza A viruses in broiler chickens and its implications for surveillance

Subtype

Pool size

Fraction FluDETECT positive (%): Fraction for 11-swab pools (%)a

Fisher’s test: AC positive greater for 11-swab pools

H5 and H7

5 or 6

118/260 (45.4%): 48/138 (34.8%)

0.026

5

57/129 (44.2%): 48/138 (34.8%)

0.074

6

61/131 (46.6%): 48/138 (34.8%)

0.033

H5

5 or 6

35/113 (31.0%): 17/69 (24.6%)

0.228

5

17/60 (28.3%): 17/69 (24.6%)

0.391

6

18/53 (34.0%): 17/69 (24.6%)

0.177

H7

5 or 6

83/147 (56.5%): 31/69 (44.9%)

0.075

5

40/69 (58.0%): 31/69 (44.9%)

0.086

6

43/78 (55.1%): 31/69 (44.9%)

0.142

  1. aIn parentheses is the FluDETECT positive fraction for pools of size 11 for that subtype grouping