Skip to main content

Table 3 Performance of the screws in intact and fractured vertebrae: Mean (standard deviation)

From: Biomechanical evaluation of monosegmental pedicle instrumentation in a calf spine model and the role of fractured vertebrae in screw stability

Parameter

Fractured vertebrae

Intact vertebrae

% Decrease

P value

Maximal insertional torque (Nm)

0.29(0.13)

0.40(0.15)

27.5

0.001

Seating torque in (Nm)

0.23(0.11)

0.28(0.13)

17.9

0.04

Axial pullout strength (N)

558(305)

646(266)

13.7

0.06