Skip to main content
  • Research article
  • Open access
  • Published:

Ultrasonographic examination of the spinal cord and collection of cerebrospinal fluid from the atlanto-occipital space in cattle

Abstract

Background

This study describes the ultrasonographic appearance of the atlanto-occipital space and ultrasound-guided collection of cerebrospinal fluid (CSF) in cattle. The atlanto-occipital space of 73 euthanized cattle (group A) and 14 live cattle with neurological disorders (group B) was examined in the sagittal and transverse planes using a 5.0-MHz convex transducer. Optimal ultrasonograms were frozen on the screen and various variables were measured in both planes using the electronic cursors. Puncture of the subarachnoid space was achieved using a spinal needle introduced in the median plane in a caudoventral direction while the spinal cord was viewed in longitudinal section. The examination of cerebrospinal fluid (CSF) was limited to gross evaluation and a red blood cell count.

Results

The spinal cord and the subarachnoid space were seen in the sagittal plane in all cattle. In group A, the mean distance between the skin and subarachnoid space was 38.6 mm, the mean depth of the subarachnoid space dorsal and ventral to the spinal cord was 8.9 mm and 8.4 mm, respectively, the mean diameter of the spinal cord was 9.9 mm and the mean diameter of the dural sac was 26.9 mm. These measurements were similar on transverse images. For collection of CSF from the subarachnoid space, the spinal cord was viewed in longitudinal section. All CSF samples from group A were colourless and clear and the median erythrocyte count was 2.5/μl. Ultrasonographic findings and results of CSF analysis were similar in group B.

Conclusions

Ultrasonography is useful for the visualisation of the spinal cord and facilitates the safe collection of CSF from the atlanto-occipital space in cattle.

Background

The examination of cerebrospinal fluid (CSF) plays a major role in the diagnosis of central nervous system diseases in cattle. There are two sites from which CSF can be collected in cattle: the first is the atlanto-occipital (AO) space and the second is the lumbosacral foramen (LSF) [1, 2]. The exact site of needle insertion at both locations is determined by skeletal landmarks but puncture is carried out blindly without visualisation of the subarachnoid space [14]. A thorough knowledge of the anatomy of the atlanto-occipital space is a prerequisite for the successful collection of CFS. The atlanto-occipital space is bordered by the occiput cranially and by the atlas caudally and is covered by the atlanto-occipital membrane, various muscles, the nuchal ligament and skin dorsally [2]. The vertebral canal contains the spinal cord surrounded by three meninges. The outermost meninx is the dura mater, which is separated from the vertebral periosteum by the epidural space [5]. The middle meninx is the dura arachnoidea, which consists of three layers; the middle layer is referred to as the subarachnoid space [6]. The pia mater is the innermost meninx. The spinal cord is a cylindrical structure with a central canal, which is continuous with the ventricular system of the brain [6].

For collection from the atlanto-occipital space, the head is ventroflexed at a 90° angle and the needle is inserted at the intersection between the dorsal midline and the line connecting the cranial edges of the wings of the atlas [2, 4] or slightly cranial to the intersection [1]. The spinal needle is introduced into the subarachnoid space parallel to the longitudinal axis of the flexed head [1, 4]. The depth at which this space is reached is not exactly predictable, and the needle is advanced slowly and carefully and monitored for free flow of CSF by removing the stylet at regular intervals [2]. Puncture of the spinal cord must be avoided because it can lead to nerve damage or even death of the patient [2, 7]. Blind aspiration of CSF from the atlanto-occipital space frequently results in contamination of the sample with blood [8, 9], which can impair the diagnosis [1014]. This emphasises the importance of the collection of uncontaminated CSF samples, which has been achieved in horses using ultrasonography. Two ultrasonographic techniques have been described in the horse [15] and both use general anaesthesia. In the first technique, the subarachnoid space is accessed from the dorsal midline while observing the median sagittal plane ultrasonographically. In the second technique, puncture of the subarachnoid space is achieved through a parasagittal oblique plane while monitoring a parasagittal oblique image. These techniques have also been used in the standing sedated horse [16]. Another study described collection of CSF between the first two cervical vertebrae using a parasagittal approach while observing the spinal cord on a cross-sectional image in the standing horse [17]. The results of those three studies showed that ultrasonography facilitated the precise puncture of the subarachnoid space and reduced complications and blood contamination of the sample. The purpose of the present study was therefore to describe the spinal cord and its surrounding structures ultrasonographically and to examine the feasibility of ultrasound-guided CSF collection in cattle.

Methods

Group A (euthanased cattle)

Group A included 73 cattle of different breeds (33 Brown Swiss, 22 Holstein Friesian, 13 Simmental, 5 other). They ranged in age from 1.2 to 13.5 years (median 4.3 years) and were euthanased for various reasons with an overdose of pentobarbital immediately before CSF was collected.

Group B (live cattle with central nervous system disease)

Group B included 14 live cattle of different breeds (8 Brown Swiss, 3 Holstein Friesian, 3 other). They ranged in age from 0.2 to 10.3 years (median 2.5 years) and underwent CSF collection because of central nervous disease.

Ultrasonographic examination and CSF collection in group A

The dead cattle were placed in lateral recumbency and the head was fixed in a normal position (head not ventroflexed, 0°) or in a mildly (about 30°) or moderately ventroflexed (about 45°) position. An attempt was first made to examine the spinal cord in a normal non-ventroflexed head position. When the resulting ultrasonogram was inadequate or when only a very short section of the spinal cord could be visualised, a mild to moderate degree of ventroflexion was applied to the head. A 15 cm × 10 cm area over the AO space was clipped and cleaned with ethanol and the area was examined ultrasonographically using a 5-MHz convex transducer (Logiq 7, GE Medical Systems, Glattbrugg) after the application of conductive gel (Aquasonic® 100, Parker Laboratories Inc.). The spinal cord and its surrounding structures were imaged and assessed in longitudinal and cross section. Optimal ultrasonograms were frozen on the screen and the following variables were measured in both planes using the electronic cursors: distance between the skin and the arachnoidea, depth of the subarachnoid space dorsal and ventral to the spinal cord, diameter of the spinal cord and diameter of the dural sac (made up by the depth of the subarachnoid space dorsal and ventral to the spinal cord and the diameter of the spinal cord). The length of the visible spinal cord was recorded. The measurements were repeated twice using newly frozen images in both planes, and means were calculated and used for analysis. The degree of ventroflexion of the head was recorded in all images. Puncture of the arachnoidea was achieved using a spinal needle (0.90 × 90 mm, Terumo®Spinal needle, Cosanum AG, Schlieren) introduced in the median plane in a caudoventral direction while the spinal cord was viewed in longitudinal section (Fig. 1). After penetration of the musculature and ultrasonographic visualisation of the tip of the needle in the subarachnoid space, the stylet was removed and 5 ml CSF was aspirated into a syringe and then transferred into an EDTA tube. If the collection was unsuccessful, the stylet was replaced and the needle withdrawn slightly or completely and re-introduced at a slightly different angle. When blood was aspirated, a new needle was used for subsequent attempts. The number of aspiration attempts was recorded.

Fig. 1
figure 1

Schematic diagram of puncture of the subarachnoid space. Schematic diagram of puncture of the subarachnoid space for collection of cerebrospinal fluid. The diagram is based on MRI images of the head of a 10-year-old Simmental cow

Ultrasonographic examination and CSF collection in group B

The cattle of group B were sedated using 0.07 to 0.10 mg/kg xylazine (Xylazin Streuli®, Streuli Pharma, Uznach) intravenously, followed by 0.05 mg/kg intramuscularly depending on the level of sedation. The sedated cattle were placed in lateral recumbency on a tilt table and all 4 feet and the head were secured (Fig. 2). The head was fixed to the table with a halter in mild ventroflexion (30°). The skin over the atlanto-occipital space was prepared and the spinal cord and surrounding structures examined ultrasonographically as described in group A. The area was then cleaned (Betadine® liquid soap, Mundipharma Medical Company, Basel) and disinfected (Betadine® standardised solution, Mundipharma Medical Company) and 5 ml lidocaine (Lidocain 2 % Streuli®, Streuli Pharma) was injected at the site of needle insertion for local anaesthesia. The spinal needle was inserted in the median plane as described in group A. The cows were returned to a standing position immediately after CSF collection, that is, within about 5 min.

Fig. 2
figure 2

Collection of cerebrospinal fluid. Collection of cerebrospinal fluid in a sedated cow in lateral recumbency. The head and legs are fixed to the operating table. The fluid is collected from the atlanto-occipital space using a spinal needle and ultrasonographic guidance provided by a 5-MHz convex transducer

Examination of cerebrospinal fluid

In group A, the examination of CSF was limited to gross evaluation (colour, viscosity) and determination of the red blood cell count using a Neubauer haemocytometer. In group B, samples were grossly evaluated and the protein concentration and white blood cell count including differentiation were determined. These latter results were not relevant for this study and are therefore not shown.

Statistical analysis

The statistical program STATA 12 (StataCorp LP, College Station, Texas, USA) was used to calculate means and standard deviations for data with normal distribution and to calculate medians for data with non-normal distribution.

Approval of the study by an ethical committee

The study was approved by an ethical committee of the canton of Zurich, Switzerland.

Results

Ultrasonographic examination and collection of CSF in group A

The spinal cord and the surrounding structures could be seen in the sagittal and transverse planes in all cattle of group A. The structures identified in the area of the atlanto-occipital space from dorsal to ventral were the skin, nuchal ligament, parts of the rectus capitis dorsalis minor and major muscles, the atlanto-occipital membrane and the vertebral canal, surrounded by the hyperechoic dura mater. In the sagittal plane, the muscles appeared as echoic structures with longitudinal striations, and the nuchal ligament was hypoechoic. The spinal cord appeared as a hypoechoic band, and some areas had a heterogeneous internal structure (Fig. 3). The subarachnoid space surrounding the spinal cord was seen dorsal and ventral to the spinal cord and was anechoic to hypoechoic and sometimes had a heterogeneous internal structure. Blood vessels often seen dorsolateral and adjacent to the dura mater were interpreted as venous sinuses based on findings in the horse [15]. The spinal cord was circular and completely surrounded by the subarachnoid space in cross-section (Fig. 4). The hyperechoic denticulate ligaments between the pia mater and dura mater were often seen on both sides of the spinal cord. The central canal was frequently seen as a hyperechoic structure in the middle of the spinal cord. The pia mater appeared as an echoic line adjacent to the spinal cord. The dura mater and arachnoid membrane were also seen as a hyperechoic line but could not be differentiated.

Fig. 3
figure 3

Longitudinal ultrasonogram of the vertebral canal. Longitudinal ultrasonogram of the vertebral canal in a 4.6-year-old Swiss Braunvieh cow at the level of the atlanto-occipital space immediately after euthanasia. Left is cranial and right is caudal. a Distance between skin and arachnoidea, b Dorsal compartment of the subarachnoid space, c Spinal cord, d Ventral compartment of the subarachnoid space, 1 Atlanto-occipital membrane, 2 Central canal, 3 Atlas, 4 Skin, 5 Nuchal ligament, 6 Major rectus capitis muscle, 7 Minor rectus capitis muscle

Fig. 4
figure 4

Transverse ultrasonogram of the vertebral canal. Transverse ultrasonogram of the vertebral canal in a 5.7-year-old Swiss Braunvieh cow at the level of the atlanto-occipital space immediately after euthanasia. a Distance between skin and arachnoidea, b Dorsal compartment of the subarachnoid space, c Spinal cord, d Ventral compartment of the subarachnoid space, 1 Atlanto-occipital membrane, 2 Venous sinus within the epidural space, 3 Dura mater and arachnoidea, 4 Central canal, 5 Denticulate ligament, 6 Skin, 7 Nuchal ligament, 8 Major rectus capitis muscle, 9 Minor rectus capitis muscle

Ventroflexion of the head was not required in 19 of 73 cattle (26 %) for ultrasonographic visualisation of the spinal cord and CSF collection. Mild ventroflexion of the head (≈30°) was used in 52 cattle (71 %) and moderate ventroflexion (≈45°) in two cases (3 %).

The mean distance between the skin and arachnoidea was 38.6 mm in the sagittal plane (Table 1). The mean height of the subarachnoid space dorsal and ventral to the spinal cord was 8.9 mm and 8.4 mm, respectively, the mean height of the spinal cord was 9.9 mm and the mean height of the entire dural sac was 26.9 mm. The spinal cord was seen in the sagittal plane over a distance of 43.1 mm. The measurements made in the transverse plane were very similar (Table 1).

Table 1 Ultrasonographic measurements of the vertebral canal at the atlanto-occipital space in euthanased cattle of group A (mm, mean ± standard deviation, median, range)

The number of punctures required for CSF collection ranged from 1 to 5 (median, 1); one puncture was required in 48 cases (66 %), two in 15 cases (21 %), three in eight cases (11 %), and of the two remaining cases (2 %), one required four punctures and the other five punctures. In eight cases that required more than one attempt, haemorrhagic fluid was first aspirated, and in the remaining 17 such cases, no fluid could be collected at first, most likely because the needle was not in the subarachnoid space.

All 73 CSF samples were grossly colourless and clear. In the 72 samples that could be analysed, the erythrocyte count varied from 0 to 820/μl (median = 2.5 erythrocytes/μl). Twenty-two samples were free of erythrocytes, 36 samples had 1 to 10, 11 samples had 11 to 86 and 3 samples had 286 to 820 erythrocytes/μl. The 8 samples that were preceded by grossly haemorrhagic samples contained no or very few erythrocytes.

Ultrasonographic examination and collection of CSF in group B

The ultrasonographic findings in the sagittal and transverse planes in the 14 cattle with central nervous system disorders were the same as in group A. Puncture of the subarachnoid space and CSF collection were achieved without difficulty in all cattle with the head in mild (30°) ventroflexion. Two attempts at CSF collection were required in two cows. Adverse reactions during needle insertion did not occur. Thirteen samples were colourless and clear and one was slightly turbid and had mild xanthochromia.

Discussion

The spinal cord and surrounding structures could be imaged ultrasonographically in all cattle in the sagittal and transverse planes. In longitudinal section, the spinal cord appeared as a hypoechoic band characterised by the hyperechoic central canal and the hyperechoic pia mater visible on the dorsal and ventral surfaces. It was circular in cross-section, and the internal structure was partially heterogeneous in both planes as described in the horse [15, 16, 18]. The subarachnoid space surrounding the spinal cord was anechoic to hypoechoic, had a heterogeneous internal structure and was bordered by the hyperechoic pia mater and the hyperechoic arachnoidea and dura mater, but the latter two structures could not be differentiated. The ultrasonographic description of the subarachnoid space of the horse varies; the space was anechoic in one study [15] and had mildly echoic striations visible in cross-section but not in longitudinal section in another study [17]. The striations were interpreted as arachnoid trabeculae between the arachnoidea and pia mater. The internal structure of the subarachnoid space appeared heterogeneous in both planes in the cows of the present study. The mean height of the subarachnoid space dorsal and ventral to the spinal cord was 8.9 mm and 8.4 mm, compared with about 1.5 cm for the dorsal section in the standing horses [16]. This difference may relate to the larger body size of horses compared with cattle. Another possible explanation is that the horses were under general anesthesia and their heads were flexed, which might have increased intracranial pressure. In neonatal foals, the height of the dorsal section of the subarachnoid space ranged from 6 to 9 mm [19], and the difference between the two age groups suggested an association between height of the subarachnoid space and body weight.

The so-called freehand technique [20] was used for centesis in both groups. Positioning the needle so that it was aligned with the sagittal orientation of the sound waves posed a few problems initially, but it did not take long to master this technique and avoid puncturing blood vessels. The blood vessels dorsolateral to the spinal cord, which were interpreted as venous sinuses based on a study in the horse [15], were occasionally and inadvertently punctured at first, and the error was quickly recognised by blood emerging from the hub of the needle. A complication was reported in horses when the angle between the needle and dura was small, which resulted in the needle pushing the dura mater ventrally, instead of perforating it [15]. This complication is referred to as tenting phenomenon and has been described in human beings [21] and in another study on horses [16]; however, these authors did not feel that the angle of the needle relative to the dura mater was the cause. The tenting phenomenon increases the risk of accidental puncture of the spinal cord, but was avoided in horses by using ultrasonographic guidance [15]. The tenting phenomenon was encountered several times in the present study, but puncture of the spinal cord could be avoided.

Ultrasound-guided collection of CSF was successful in the first or second attempt in most cases. All but one sample were clear and colourless and all had no or minimal microscopic evidence of blood contamination. Compared with samples from horses, the erythrocyte count of CSF samples was higher [15, 16] or similar [17] in the cattle of the present study, but smaller than in samples collected using blind puncture without ultrasonographic guidance [8, 9]. A minimum erythrocyte count of about 2000 to 3000 cells/μl is required to render a CSF sample grossly discoloured or turbid [10, 11, 22], and blood contamination often goes macroscopically unnoticed [9, 11, 12].

In the live cows of group B, ultrasonographic guidance of the puncture was superior to blind puncture because only mild ventroflexion of the head and therefore only mild sedation was required. In contrast, blind puncture requires marked ventroflexion of the head of up to 90° [1, 2, 4], which results in stress, resistance to handling and possible respiratory depression in the animal. Furthermore, twitching movements, which are common during blind puncture of the dura mater, did not occur with ultrasonographic guidance. These movements are most likely caused by accidental puncture of the spinal cord.

Conclusion

The spinal cord and its surrounding structures were readily identified using ultrasonography. Collection of CSF was successful in all cases and blood contamination of the fluid was avoided or kept to a minimum under ultrasound guidance. All collected samples could be used for diagnostic purposes. Furthermore, ultrasound guidance eliminated the need for marked ventroflexion of the head, which in turn minimised defensive reactions that commonly occur when the blind technique is used. Ultrasound-guided puncture of the subarachnoid space from the atlanto-occipital site is convenient and safe and therefore the method of choice for collection of CSF samples in cattle.

References

  1. Vandevelde M, Jaggy A, Lang J. Untersuchung des Liquor cerebrospinalis. In: Vandevelde M, Jaggy A, Lang J, editors. Veterinärmedizinische Neurologie. Berlin: Parey Verlag; 2001. p. 63–9.

    Google Scholar 

  2. De Lahunta A, Glass E. Cerebrospinal fluid and hydrocephalus. In: Delahunta A, Kent M, Glass EN, editors. Veterinary neuroanatomy and clinical neurology. St Louis: Saunders Elsevier; 2009. p. 54–76.

    Chapter  Google Scholar 

  3. Di Terlizzi R, Platt SR. The function, composition and analysis of cerebrospinal fluid in companion animals: Part II – Analysis. Vet J. 2009;180:15–32.

    Article  PubMed  Google Scholar 

  4. Kumar V, Kumar N. Diagnostic value of cerebrospinal fluid evaluation in veterinary practice: An overview. J Adv Vet Res. 2012;2:213–7.

    Google Scholar 

  5. Stoffel MH. Meningen. In: Stoffel MH, editor. Funktionelle Neuroanatomie für die Tiermedizin. Stuttgart: Enke; 2011. p. 100–5.

    Google Scholar 

  6. König HE, Liebich HG, Červeny C. Nervensystem (Systema nervosum). In: König HE, Liebich HG, editors. Anatomie der Haussäugetiere: Lehrbuch und Farbatlas für Studium und Praxis. Stuttgart: Schattauer; 2005. p. 485–556.

    Google Scholar 

  7. Luján Feliu-Pascual A, Garosi L, Dennis R, Platt S. Iatrogenic brainstem injury during cerebellomedullary cistern puncture. Vet Radiol Ultrasound. 2008;49:467–71.

    Article  PubMed  Google Scholar 

  8. Averill DR. Examination of cerebrospinal fluid. In: Kirk RW, editor. Current veterinary therapy: small animal practice. Philadelphia: WB Saunders Company; 1974. p. 645–8.

    Google Scholar 

  9. Kornhuber ME, Kornhuber J, Kornhuber AW, Hartmann GM. Positive correlation between contamination by blood and amino acid levels in cerebrospinal fluid of the rat. Neurosci Lett. 1986;69:212–5.

    Article  PubMed  CAS  Google Scholar 

  10. Ylitalo P, Heikkinen ER, Myllylä VV. Evaluation of sucessive collections of cisternal cerebrospinal fluid in rats, rabbits, and cats. Exp Neurol. 1976;50:330–6.

    Article  PubMed  CAS  Google Scholar 

  11. Miller MM, Sweeney CR, Russell GE, Sheetz RM, Morrow JK. Effects of blood contamination of cerebrospinal fluid on western blot analysis for detection of antibodies against Sarcocystis neurona and on albumin quotient and immunoglobulin G index in horses. J Am Vet Med Assoc. 1999;215:67–71.

    PubMed  CAS  Google Scholar 

  12. Sweeney CR, Russell GE. Differences in total protein concentration, nucleated cell count, and red blood cell count among sequential samples of cerebrospinal fluid from horses. J Am Vet Med Assoc. 2000;217:54–7.

    Article  PubMed  CAS  Google Scholar 

  13. Finno CJ, Packham AE, David Wilson W, Gardner IA, Conrad PA, Pusterla N. Effects of blood contamination of cerebrospinal fluid on results of indirect fluorescent antibody tests for detection of antibodies against Sarcocystis neurona and Neospora hughesi. J Vet Diagn Invest. 2007;19:286–9.

    Article  PubMed  Google Scholar 

  14. Doyle C, Solano-Gallego L. Cytologic interpretation of canine cerebrospinal fluid samples with low total nucleated cell concentration, with and without blood contamination. Vet Clin Pathol. 2009;38:392–6.

    Article  PubMed  Google Scholar 

  15. Audigié F, Tapprest J, Didierlaurent D, Denoix JM. Ultrasound-guided atlanto-occipital puncture for myelography in the horse. Vet Radiol Ultrasound. 2004;45:340–4.

    Article  PubMed  Google Scholar 

  16. Depecker M, Bizon-Mercier C, Couroucé-Malblanc A. Ultrasound-guided atlanto-occipital puncture for cerebrospinal-fluid analysis on the standing horse. Vet Rec. 2014;174:45.

    Article  PubMed  CAS  Google Scholar 

  17. Pease A, Behan A, Bohart G. Ultrasound-guided cervical centesis to obtain cerebrospinal fluid in the standing horse. Vet Radiol Ultrasound. 2012;53:92–5.

    Article  PubMed  Google Scholar 

  18. Bucca S, Fogarty U, Farelly BT. Ultrasound examination of the atlanto-occipital space. In: McAuliffe SB, Slovis NM, editors. Color atlas of diseases and disorders of the foal. Philadelphia: Saunders Elsevier; 2008. p. 349–50.

    Google Scholar 

  19. Sgorbini M, Marmorini P, Rota A, Briganti A, Corazza M. Ultrasound measurements of the dorsal subarachnoid space depth in healthy trotter foals during the first week of life. J Equine Vet Sci. 2011;31:41–3.

    Article  Google Scholar 

  20. Tucker RL. Ultrasound-guided biopsy. In: Rantanen NW, McKinnon AO, editors. Equine diagnostic ultrasonography. Baltimore: Williams & Willkins; 1998. p. 649–53.

    Google Scholar 

  21. Orrison WW, Eldevik OP, Sackett JF. Lateral C1-2 puncture for cervical myelography. Part III: Historical, anatomic, and technical considerations. Radiology. 1983;146:401–8.

    Article  PubMed  CAS  Google Scholar 

  22. Patten BM. How much blood makes the cerebrospinal fluid bloody? J Am Med Assoc. 1968;206:378.

    Article  CAS  Google Scholar 

Download references

Acknowledgements

We thank the staff of the veterinary medical laboratory for analysis of the samples, Jeanne Peter Zocher, Anne Seeger and Michelle Aimée Oesch for help with labelling the ultrasonograms, Dr. Hans Geyer for his guidance with the interpretation of the anatomical structures, the agricultural assistants for their help with the examinations, Mike Patthey for the MRI examination of the bovine head, Dr. Matthias Dennler for interpretation of the MRI scans and Matthias Haab for drawing Fig. 2.

Sources of fundings

This study was financed by the University of Zurich, Switzerland.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ueli Braun.

Additional information

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

UB initiated, planned and supervised the study and co-authored the manuscript with the other authors; JA completed the clinical part of the study as part of her master thesis and collated the findings; CB supported JA in the clinical part of the study. All authors contributed equally to this study and read and approved the final manuscript.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Braun, U., Attiger, J. & Brammertz, C. Ultrasonographic examination of the spinal cord and collection of cerebrospinal fluid from the atlanto-occipital space in cattle. BMC Vet Res 11, 227 (2015). https://0-doi-org.brum.beds.ac.uk/10.1186/s12917-015-0545-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://0-doi-org.brum.beds.ac.uk/10.1186/s12917-015-0545-z

Keywords